In brief
- Plan at least 60-80 m³/h of extraction capacity per kW of thermal load, and size the hood to the actual cooking equipment.
- Fire dampers at compartment penetrations and easily removable grease filters are core SOLAS II-2 requirements for galley exhaust systems.
- Supply make-up air equal to 80-90% of exhaust capacity; otherwise negative pressure reduces extraction and disturbs flames.
Contents
- 1. Why Is Ventilation Critical in a Marine Galley?
- 2. Airflow Calculation: CFM and m³/h
- 3. SOLAS and Class Society Standards
- 4. Hood Selection and Technical Criteria
- 5. Exhaust Fan and Duct System
- 6. Make-Up Air: Balancing the Fresh Air Supply
- 7. Installation and Fitting Rules
- 8. Periodic Maintenance
- Frequently asked questions
A ship's galley, or marine kitchen, is an enclosed and restricted space that generates high heat, humidity and grease vapour. Without adequate ventilation, these conditions directly harm crew health, fire safety and the service life of the galley equipment.
A marine galley ventilation system is more than a hood and an extraction fan. Correct airflow calculation, SOLAS fire safety requirements, class society standards and compatibility with the ship's electrical system must all be addressed together. In this guide we explain these topics step by step.
1. Why Is Ventilation Critical in a Marine Galley?
If ventilation is inadequate in a restaurant kitchen ashore, a window or door is opened. On a ship this is not possible. The galley is inside a closed steel box, and the heat, humidity, grease vapour and combustion gases it produces can leave only through purpose-designed exhaust ducts.
The consequences of inadequate ventilation:
- Fire risk: Grease accumulating in the hood grease filters is a source of ignition. SOLAS contains specific provisions on this.
- Crew health: A build-up of CO, NO₂ and grease vapour causes respiratory problems in the long term.
- Equipment life: Condensing moisture and grease cause premature failure in galley equipment and electrical systems.
- Class survey: An inadequate ventilation system can be grounds for a non-conformity at class survey.
2. Airflow Calculation: CFM and m³/h
Ventilation capacity is expressed in two units: CFM (cubic feet per minute, the American/maritime standard) and m³/h (cubic metres per hour, the European standard). Conversion: 1 CFM ≈ 1.699 m³/h.
2.1 Calculation Methods
Marine galley ventilation capacity can be calculated using three basic methods:
| Method | Formula / Rule | Use Case |
|---|---|---|
| Volume-based | Galley volume × 30-60 air changes per hour | Preliminary calculation and small galleys |
| Thermal-load-based | Total thermal load (kW) × 0.8 m³/h/kW factor | Projects with intensive cooking equipment |
| Hood capture velocity | Hood opening area (m²) × 0.3-0.5 m/s capture velocity | Hood sizing |
2.2 Reference Values by Vessel Type
| Vessel Type | Crew | Estimated Extraction Capacity | Air Changes |
|---|---|---|---|
| Small cargo ship | 10-15 persons | 1,500 – 2,500 m³/h | 30-40 per hour |
| Medium-size cargo/container ship | 20-30 persons | 3,000 – 5,000 m³/h | 40-50 per hour |
| Offshore support vessel | 50+ persons | 6,000 – 10,000 m³/h | 50-60 per hour |
| Ferry / passenger ship | Variable | Project-specific calculation | 60+ per hour |
| Yacht / superyacht | 5-20 persons | 800 – 2,000 m³/h | 25-35 per hour |
* These values are given for preliminary calculation only. For final sizing, equipment thermal loads and galley geometry must be assessed together.
3. SOLAS and Class Society Standards
Marine galley ventilation systems must be designed in accordance with SOLAS II-2 (fire protection) and the galley ventilation rules of the class societies.
Key SOLAS II-2 Requirements
- Hoods over cooking equipment must be made of fire-resistant material or be fitted with a fire suppression system.
- Exhaust ducts must be fitted with fire dampers where they pass through compartment boundaries.
- To prevent grease build-up, hood filters must be easy to remove and clean.
- Integration of automatic fire extinguishing systems (Ansul or similar) is mandatory on large commercial ships.
| Class Society | Hood Standard | Exhaust Duct Thickness |
|---|---|---|
| DNV GL | DNVGL-RU-SHIP Pt.4 Ch.8 | Min. 1.5 mm steel |
| Lloyd's Register | LR Rules Pt.5 Ch.16 | Min. 1.5 mm steel |
| Bureau Veritas | BV NR 566 | Min. 1.5 mm steel |
| Türk Loydu | TL Machinery Rules, Section 13 | Min. 1.5 mm steel |
4. Hood Selection and Technical Criteria
The hood is the most critical component of the ventilation system. It must be correctly sized to capture grease, vapour and heat at the source.
4.1 Hood Types
| Type | Application | Advantage |
|---|---|---|
| Wall-mounted | Cooking lines against a bulkhead | Compact, ideal for restricted galleys |
| Island (suspended from the deckhead) | Centrally located cooking islands | Capture from all sides, for large galleys |
| Built-in (recessed) | Yacht and superyacht projects | Aesthetic, no visible ductwork |
| Low-profile | Vehicle deck and boat projects | Suits low deckhead clearance |
4.2 Filter Systems
Three filter types are used in marine hoods:
- Baffle filter: The most common type. Grease particles strike the baffle surface and run off through the drainage channel. Removable and dishwasher-cleanable. SOLAS compliant.
- Cassette filter: Additional protection against finer grease particles. Fitted behind the baffle filter.
- Activated carbon filter: An additional layer for odour removal. Preferred in yacht projects for interior comfort.
5. Exhaust Fan and Duct System
The exhaust fan is the heart of the system. Land-type industrial fans cannot be used in marine applications.
Points to Consider When Selecting a Fan
- Voltage / frequency: 440V/60Hz or 380V/50Hz; the fan must suit the ship's electrical system
- Grease resistance: Fan blades and casing must be made of material resistant to grease vapour
- Static pressure capacity: It must cover the static pressure loss calculated from duct length and number of bends
- Speed control: Variable speed via a frequency inverter, with automatic adjustment to cooking intensity
- Vibration isolation: Marine fans must be mounted with vibration-damping connectors
Duct System
| Parameter | Recommended Value | Explanation |
|---|---|---|
| Duct air velocity | 5–8 m/s | Keeps noise low and prevents grease build-up |
| Duct wall thickness | Min. 1.5 mm steel | Class society standard |
| Number of bends | As few as possible | Every bend creates static pressure loss |
| Cleaning access | Cleaning hatch every 3 metres | SOLAS grease build-up prevention rule |
| Fire damper | Mandatory at compartment penetrations | Required by SOLAS II-2 |
6. Make-Up Air: Balancing the Fresh Air Supply
The most common mistake is to design the exhaust system and forget the fresh air inlet. If fresh air equal to the volume removed by the exhaust is not supplied, the system operates under negative pressure: doors will not open, extraction performance drops and flames flicker.
Golden rule: Provide make-up air equal to 80-90% of the exhaust capacity. The remaining 10-20% keeps the galley at a slight negative pressure, which prevents galley air from leaking into adjacent spaces.
| Make-Up Air Source | Advantage | Disadvantage |
|---|---|---|
| Natural transfer (gap under the door) | Simple, no cost | Uncontrollable, galley pressure fluctuates |
| Dedicated make-up air duct system | Controlled and balanced flow | Additional cost and installation |
| Air-conditioning system circuit | Heating/cooling integration | Requires coordination with the HVAC system |
7. Installation and Fitting Rules
Critical rules to observe when installing a marine ventilation system:
- The distance between the lower edge of the hood and the cooking surface should be 650–900 mm (depending on type and thermal load)
- The hood should be at least 150 mm wider than the cooking equipment on each side
- The exhaust duct should be designed as short as possible with few bends
- Fire dampers must be fitted at all compartment penetrations
- The fan should be positioned so that it is the highest point of the system, to prevent grease build-up
- The duct system should be fitted with a cleaning hatch every 3 metres
- The installation should be approved by the naval architect
- Class society survey should be planned in advance
8. Periodic Maintenance
Even the best-designed ventilation system becomes a fire risk if it is left unmaintained. Recommended maintenance schedule:
| Maintenance Item | Frequency | Note |
|---|---|---|
| Baffle filter cleaning | Weekly for heavy use | Dishwasher compatible |
| Hood interior cleaning | Monthly | Especially the grease drainage channel |
| Exhaust duct internal cleaning | Every 6 months | Via the cleaning hatches |
| Fan inspection and lubrication | Every 3 months | Including vibration and noise checks |
| Fire damper test | Every 6 months | The class society may require it |
| Make-up air balance check | Annually | With a measuring instrument |
Related content:
→ Marine Galley Equipment — Technical details of ranges, ovens and cooking groups
→ Custom-Size Stainless Steel Fabrication — Custom AISI 316L hood manufacture
→ Marine Galley Range Guide
A Ventilation Solution for Your Project
Share your galley plan, equipment list and class requirements, and we will design a custom-size hood and ventilation system.
Frequently asked questions
Can a standard land-type hood be used on a ship?
No. Land-type hoods are not designed to withstand a ship's roll and vibration. They also fail to meet the SOLAS requirements on exhaust duct wall thickness and fire dampers, which gives grounds for a non-conformity at class survey.
How large should the hood be?
The hood should be at least 150 mm wider than the cooking equipment beneath it on each side. Its height should be set so that the distance between the cooking surface and the lower edge of the hood is 650-900 mm. Exact dimensions are determined by the thermal load calculation.
Why is make-up air important?
If fresh air equal to the volume taken by the exhaust system is not supplied, excessive negative pressure builds up in the galley. Extraction performance then drops, doors will not open and flames can flicker. Plan make-up air at 80-90% of the exhaust capacity.
How often should grease filters be cleaned?
In heavily used commercial ship galleys, baffle filters should be cleaned at least once a week. Uncleaned filters create a serious fire risk because of grease build-up.
What is needed to order a custom-size hood?
A technical drawing of the galley or an on-site survey, the list of cooking equipment with thermal ratings, the ship's electrical system (440V/60Hz or 380V/50Hz) and the project's class society are sufficient. If there is no drawing, we carry out an on-site survey.
Do you install on shipyard projects in Türkiye?
Yes. From our production centre in Gebze we deliver and install on site at shipyards in Türkiye and on export projects worldwide. Planning follows the shipyard's project schedule.